<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">

<html>
  <head>
    <meta name="generator" content="HTML Tidy, see www.w3.org">
    <title>Remote Logger Operation</title>
    <meta name="GENERATOR" content=
    "Modular DocBook HTML Stylesheet Version 1.7">
    <link rel="HOME" title=" LPRng Reference Manual" href=
    "index.htm">
    <link rel="PREVIOUS" title=
    "I want to replace lp, lpstat, etc, but my programs need them"
    href="x10938.htm">
    <link rel="NEXT" title="Logger Messages" href="x10991.htm">
  </head>

  <body class="CHAPTER" bgcolor="#FFFFFF" text="#000000" link=
  "#0000FF" vlink="#840084" alink="#0000FF">
    <div class="NAVHEADER">
      <table summary="Header navigation table" width="100%" border=
      "0" cellpadding="0" cellspacing="0">
        <tr>
          <th colspan="3" align="center">LPRng Reference Manual: 24
          Sep 2004 (For LPRng-3.8.28)</th>
        </tr>

        <tr>
          <td width="10%" align="left" valign="bottom"><a href=
          "x10938.htm" accesskey="P">Prev</a></td>

          <td width="80%" align="center" valign="bottom">
          </td>

          <td width="10%" align="right" valign="bottom"><a href=
          "x10991.htm" accesskey="N">Next</a></td>
        </tr>
      </table>
      <hr align="LEFT" width="100%">
    </div>

    <div class="CHAPTER">
      <h1><a name="REMOTELOGGER"></a>Chapter 21. Remote Logger
      Operation</h1>

      <div class="TOC">
        <dl>
          <dt><b>Table of Contents</b></dt>

          <dt>21.1. <a href="remotelogger.htm#LOGGER">Logger
          Network Communication</a></dt>

          <dt>21.2. <a href="x10991.htm">Logger Messages</a></dt>

          <dt>21.3. <a href="x10996.htm">Message Format</a></dt>

          <dt>21.4. <a href="x11024.htm">Dump Messages</a></dt>

          <dt>21.5. <a href="x11027.htm">LPD Messages</a></dt>

          <dt>21.6. <a href="x11032.htm">Job Status Messages -
          UPDATE</a></dt>

          <dt>21.7. <a href="x11044.htm">Printer Status Messages -
          PRSTATUS</a></dt>
        </dl>
      </div>

      <p>Several sites have wanted a way to provide central logging
      of job status and/or information. In order to do this, the
      following functionality is implemented in <b class=
      "APPLICATION">LPRng</b>.</p>

      <div class="SECT1">
        <h1 class="SECT1"><a name="LOGGER">21.1. Logger Network
        Communication</a></h1>

        <p>Options used:</p>

        <ul>
          <li>
            <p><var class="LITERAL">logger_destination=</var><span
            class="emphasis"><i class="EMPHASIS">logger information
            destination</i></span></p>
          </li>

          <li>
            <p><var class="LITERAL">logger_pathname=</var><span
            class="emphasis"><i class="EMPHASIS">pathname of temp
            file for log information</i></span></p>
          </li>

          <li>
            <p><var class="LITERAL">logger_max_size=</var><span
            class="emphasis"><i class="EMPHASIS">max size in K of
            temp file for log information</i></span></p>
          </li>

          <li>
            <p><var class="LITERAL">logger_timeout=</var><span
            class="emphasis"><i class="EMPHASIS">time between
            connection attempts</i></span></p>
          </li>
        </ul>
        <br>
        <br>

        <p>The printcap/configuration variable <var class=
        "LITERAL">logger_destination</var> specifies a destination
        in the standard <var class="LITERAL">host%port</var>
        notation used by <b class="APPLICATION">LPRng</b>. Host is
        the destination host, and can be a name or IP address. Port
        is the port on the destination host. A TCP/IP connection is
        made to the indicated port.</p>

        <p>Log information is save in a temporary file specified by
        <var class="LITERAL">logger_path</var>, and up to <var
        class="LITERAL">logger_max_size</var> K bytes of data will
        be saved.</p>

        <p>If a connection cannot be made to the <var class=
        "LITERAL">logger_destination</var>, then every <var class=
        "LITERAL">logger_timeout</var> seconds a new connection
        attempt will be made. If <var class=
        "LITERAL">logger_timeout</var> is 0, then a connection
        attempt will be made every time new data arrives to be
        logged.</p>
      </div>
    </div>

    <div class="NAVFOOTER">
      <hr align="LEFT" width="100%">

      <table summary="Footer navigation table" width="100%" border=
      "0" cellpadding="0" cellspacing="0">
        <tr>
          <td width="33%" align="left" valign="top"><a href=
          "x10938.htm" accesskey="P">Prev</a></td>

          <td width="34%" align="center" valign="top"><a href=
          "index.htm" accesskey="H">Home</a></td>

          <td width="33%" align="right" valign="top"><a href=
          "x10991.htm" accesskey="N">Next</a></td>
        </tr>

        <tr>
          <td width="33%" align="left" valign="top">I want to
          replace lp, lpstat, etc, but my programs need them</td>

          <td width="34%" align="center" valign="top">&nbsp;</td>

          <td width="33%" align="right" valign="top">Logger
          Messages</td>
        </tr>
      </table>
    </div>
  </body>
</html>



syntax highlighted by Code2HTML, v. 0.9.1